Site Acceptance Testing Technician

Crusoe
•$46•Onsite

About The Position

The Field Service Technician – Mechanical Integration & Field Site Acceptance supports field deployment, mechanical integration, site acceptance testing (SAT), and field service for OEM data center infrastructure. The role operates at client and enterprise data center sites and supports installation and mechanical validation of modular data centers, power distribution skids, high-density GPU/server racks, thermal containment systems, and cooling manifolds. The position focuses on mechanical installation, precise physical alignment, site acceptance protocols, and non-licensed low-voltage support for 24VDC and signal control circuits. It operates strictly within a non-certified electrical scope: high-voltage electrical connections and certified electrician tasks are excluded. The technician works with client facility teams, general contractors, and commissioning engineers; documents test results and field work; and follows EHS, PPE, and site-specific LOTO requirements. Travel to client data center project locations is required as needed.

Requirements

  • High school diploma or equivalent.
  • 2–5+ years of practical field service, mechanical installation, or field integration experience in data centers, critical facilities, industrial power, or HVAC environments.
  • Hands-on proficiency with mechanical hand and power tools, torque wrenches, precision measurement devices, and leveling equipment.
  • Ability to read and interpret mechanical assembly drawings, structural layouts, and field installation procedures.
  • Ability to lift up to 50 lbs unassisted, work in confined spaces inside modular units, and safely work at elevated heights.
  • Willingness and ability to travel to client data center project locations as required.

Nice To Haves

  • Trade school diploma or technical certification in mechanical technology, field service, or industrial maintenance.
  • Direct field experience with modular data centers, power skids, server/GPU rack containment, and fluid distribution manifolds.
  • Familiarity with low-voltage wiring fundamentals, control schematics, wire stripping, terminal block wiring, and cable lacing.
  • Hands-on experience using digital multimeters for non-energized continuity verification and low-voltage (24VDC/signal) troubleshooting.
  • Working knowledge of liquid cooling loops, pressure testing procedures, and quick-disconnect manifold connections.
  • Active OSHA 10 or OSHA 30 card, NFPA 70E awareness, and signalperson or rigging safety training.

Responsibilities

  • Position, anchor, and precisely align modular data centers, GPU/server rack assemblies, power skids, and containment structures on site.
  • Rig, position, level, and secure heavy OEM sub-assemblies and fluid distribution manifolds using leveling gear, torque tools, and field rigging equipment.
  • Install cooling lines, quick-disconnect fittings, and fluid interconnects according to engineering drawings and torque specifications.
  • Conduct structural integrity checks, vibration-isolation verifications, and environmental sealing of modular enclosures.
  • Execute SAT protocols to verify mechanical integrity and installation readiness before customer handover.
  • Perform mechanical and visual quality inspections during uncrating, landing, and positioning at client facilities.
  • Document SAT outcomes, maintain field test logs, and compile punch lists of mechanical or cosmetic anomalies.
  • Work with client data center facility teams, general contractors, and commissioning engineers to resolve field integration issues.
  • Support OEM low-voltage control circuits, sensor loops, and signal lines as non-licensed field support.
  • Perform basic multimeter continuity checks and voltage measurements on non-energized control loops and terminal blocks.
  • Strip wires, terminate terminal blocks, crimp, lace wires, and manage cables inside OEM control cabinets, while observing defined electrical scope limits.
  • Act as the primary technical field representative for OEM equipment landing, mechanical troubleshooting, and field modification kits.
  • Complete daily site logs, field service reports, redline drawing revisions, and material tracking forms.
  • Follow EHS guidelines, PPE rules, and site-specific LOTO procedures.
  • Travel to client data center project locations as required.

Benefits

  • Competitive compensation and equity packages
  • Restricted Stock Units
  • Paid time off, paid holidays, and leave of absence programs
  • Comprehensive health, dental, and vision insurance
  • Employer contributions to HSA account
  • Paid parental leave
  • Paid life insurance, short-term disability, and long-term disability
  • Professional development and tuition reimbursement
  • Mental health and wellness support
  • Commuter benefits (parking and transit)
  • Cell phone stipend
  • 401(k) retirement plan with company match up to 4% of salary
  • Volunteer time off
  • Global travel insurance and emergency assistance
  • Daily meals allowance
  • Additional perks and programs specific to location
© 2026 Teal Labs, Inc
Privacy PolicyTerms of Service