QA/QC Inspector II

ACCO Engineered Systems•Cedar City, UT

About The Position

The QA/QC Inspector II plans and performs inspections, examinations, and testing for an assigned project, system, or shop scope and maintains the resulting quality records. The role represents ACCO in inspecting pipe and equipment installation, welding and brazing, and subcontractor installation and quality. It participates in the general contractor’s project quality program and documents installation activities and objective evidence supporting acceptance, testing, and turnover. This is the working inspection level, above Inspector I and below Inspector III. The position independently determines and sequences inspections within its assigned scope in coordination with the construction schedule, and is accountable for complete records. When an Inspector I is assigned, the position provides daily technical direction; when an Inspector III is assigned, it works to that inspector’s plan. The role supports fabrication, installation, and project management as part of the project team. Local project leadership provides day-to-day coordination on site, while inspection decisions, acceptance or rejection, and quality records follow the QA/QC reporting line. Quality conflicts are escalated the same day. The position plans and performs inspections, identifies and honors hold and witness points, examines joints and installation workmanship, conducts receiving inspections, coordinates testing and nondestructive examination, documents nonconformances, and develops test packages and turnover records as work progresses. It communicates with the general contractor’s quality representative and project team, provides inspection demand input for look-ahead planning, and may coach an assigned Inspector I. The role may reject nonconforming material or workmanship, hold work at inspection points, require re-inspection or retesting, and stop nonconforming work in progress with immediate notification to the Inspector III and Project Manager. It prepares nonconformance reports but does not issue, disposition, or close them. The position does not approve or issue welding procedure specifications or procedure qualification records; qualify welders or brazers unless holding a current CWI and receiving specific written delegation; approve repairs, deviations, waivers, or field changes; sign the final quality letter or turnover acceptance; or commit ACCO to schedule or cost positions. Travel varies with business needs and assignments and may include overnight travel to offices, branches, fabrication facilities, and project sites. Work location varies by assignment. Hours and shifts follow area project requirements and applicable law; overtime, shift work, and weekend coverage occur based on the project schedule. The role is non-exempt, and work and applicable travel time between sites during the workday must be recorded accurately. The job involves active construction sites and fabrication shops, including elevated work areas and confined spaces, with required fall protection and personal protective equipment.

Requirements

  • At least five years of quality-control experience, including at least three years focused on ASME B31 piping codes, industrial and commercial construction, fabrication, welding, or nondestructive testing.
  • Current ASNT or ACCP VT Level II certification and/or current certification as an AWS QC1 Certified Welding Inspector (CWI).
  • Working knowledge of ASME B31.1, B31.3, B31.5, and B31.9, and ASME Section IX as it applies to verifying welder qualification and continuity.
  • Command of weld, braze, and mechanical-joint acceptance criteria for applicable codes and specifications.
  • Working knowledge of nondestructive examination methods and their limitations, and pressure-testing practices and documentation.
  • Working knowledge of material control, traceability, preservation, and contamination control for stainless, high-purity, and nonmetallic systems.
  • Ability to read and interpret isometrics, P&IDs, shop drawings, specifications, codes, and procedure manuals.
  • Ability to write routine reports and correspondence.
  • Annual Jaeger J1 near-vision examination.
  • Regular and routine attendance.
  • Valid driver’s license and reliable transportation to assigned project sites.
  • Ability to access active construction sites and fabrication shops, including elevated work areas and confined spaces, using required fall protection and personal protective equipment.
  • Ability to meet the stated physical demands, including lifting and moving up to 10 pounds frequently and up to 25 pounds occasionally, and regularly walking, climbing stairs, sitting, stooping, kneeling, crouching, or crawling.

Nice To Haves

  • Both VT Level II and CWI certifications.
  • ICC Mechanical – Commercial certification.
  • Familiarity with PT, MT, UT, and RT sufficient to read a third-party examination report and understand what was examined, the criteria applied, and the result; certification to perform these methods is not required.
  • Experience on semiconductor, high-purity, cleanroom, or mission-critical data center projects.
  • OSHA 30, confined space, and first aid/CPR training.
  • Experience with Box, Bluebeam, Smartsheet, Procore, or PlanGrid.
  • Conversational Spanish.

Responsibilities

  • Plan and conduct inspections, examinations, and testing for the assigned scope in sequence with the construction schedule.
  • Identify applicable Inspection and Test Plan hold and witness points and ensure they are honored.
  • Visually examine and document welded, brazed, soldered, and mechanical joints; fit-up and alignment; supports and hangers; bolt-up and torque; and general workmanship.
  • Perform receiving inspection and maintain the confirmed compliant material log for the assigned scope.
  • Coordinate and witness pressure testing, cleaning, flushing, and blowing in accordance with applicable procedures.
  • Coordinate nondestructive examination requests, witness examinations when required, and review third-party reports for completeness and correct acceptance criteria.
  • Perform first-in inspections on new crews, processes, and materials to identify errors before they are repeated.
  • Submit a daily inspection report with photographs for every project day worked, filed the same day.
  • Keep the weld log and weld map current with installed work, including welder traceability for every joint.
  • Maintain the inspection request and notification log for the assigned scope.
  • Document nonconformances with description, location, code or specification reference, and photographic evidence; track them to closure and record closure evidence.
  • Assemble test packages and turnover documentation progressively as work is installed.
  • Review design documentation, submittals, and vendor documentation against stated requirements and raise discrepancies before installation.
  • Engage with the general contractor’s quality representative on inspection planning, compliance, nonconformance management, and audits for the assigned scope.
  • Attend project meetings concerning upcoming activities, status, and deadlines, and report inspection demand for the coming three weeks.
  • Provide inspection demand input to the QA/QC three-week look-ahead for the assigned project.
  • Communicate significant issues promptly to QA/QC leadership, with a recommendation when warranted.
  • Provide quality expectations, coaching, and day-to-day work direction to an assigned Inspector I.
  • Maintain working knowledge of applicable codes, specifications, and industry standards, and keep personal certifications and training current.
  • Recommend process improvements identified during inspection activities.
  • Participate in ACCO safety programs and demonstrate commitment to a goal of zero injuries or incidents.
  • Identify and document nonconforming conditions, prepare nonconformance reports with supporting code references and evidence, and leave issuance and disposition to the QA/QC Area Supervisor or above jointly with the Project Team.
  • Reject material and workmanship that does not conform to specifications, submittals, drawings, or applicable codes.
  • Place a hold on work and require that work not proceed past a hold or witness point until inspection is performed and recorded.
  • Require re-inspection or retesting following repair or rework, and stop nonconforming work in progress with immediate notification to the Inspector III and Project Manager.
  • Submit inspection requests and schedule third-party examination in coordination with QA/QC leadership.
  • Travel as business needs require to the primary office, regional branch offices, fabrication facilities, and project sites.
  • Accurately record hours worked, including time spent traveling between sites during the workday.

Benefits

  • Sign-on bonus of $3,000 for Inspector II, paid after six months of employment if role expectations are met.
  • Annual pay rate reviews and increases.
  • Discretionary performance bonuses following regular performance evaluations.
  • Relocation packages for qualified roles.
  • Competitive per diem allowances for project-based roles to support housing needs.
© 2026 Teal Labs, Inc
Privacy PolicyTerms of Service