About The Position

The OSP Fiber & Telecommunications Engineer plans and coordinates copper and fiber physical-layer infrastructure for new power plants and AI datacenter campuses. The scope includes SCADA, protection, metering, plant control communications, auxiliary and support systems, and inter-building or site-to-site links serving those systems. It excludes fiber, copper, pathways, structured cabling, high-density trunks, and compute-fabric connectivity inside data halls. Responsibility ends at the hall demarc or in plant and campus spaces serving OT and auxiliary systems. Work includes outside plant and non-data-hall inside plant pathways such as conduit, duct banks, manholes, handholes, aerial routes, cable tray, risers, and MDF/IDF or control-room spaces. The engineer plans copper for industrial Ethernet and control applications and fiber—single-mode preferred for OSP and longer runs—including splice plans, termination, labeling, and test criteria. The position coordinates design, procurement, installation, and commissioning with civil, electrical, mechanical, controls, and construction teams, and manages low-voltage and fiber contractors and documentation. The role is onsite in Southaven, Mississippi. The stated project time frame is December 2026 through March 2027. Work authorization is limited to U.S. citizens or Green Card holders; third-party inquiries are not accepted.

Requirements

  • Bachelor's degree in engineering, telecommunications, or a related field, or equivalent experience in industrial communications infrastructure.
  • At least 5 years designing or coordinating fiber and copper infrastructure on capital projects in industrial, utility, power-generation, substation, or large-campus environments.
  • Demonstrated OSP fiber experience, including route and pathway planning, splice-plan oversight, OTDR and loss-budget review, and underground or aerial construction coordination.
  • Experience with industrial or structured copper used for control and support networks, including grounding, shielding, and routing near high-voltage or electrically noisy equipment.
  • Working understanding of physical-layer needs for SCADA or similar control systems, including path diversity, environmental hardening, and separation from power infrastructure.
  • Proven ability to coordinate multidisciplinary design and construction involving civil, electrical, and controls teams and to produce clear cable schedules, drawings, and as-builts.
  • Ability to read and mark up construction drawings and maintain scope boundaries with adjacent trades and IT/OT teams.
  • U.S. citizenship or Green Card work authorization.

Nice To Haves

  • BICSI RCDD or OSP, FOA CFOT/CFOS, or an equivalent physical-layer credential.
  • Direct experience on power plants, substations, or hyperscale or large datacenter campuses outside the data hall.
  • Familiarity with NERC CIP physical considerations, IEC 61850 at the cabling layer, or utility communications practices.
  • Experience with permitting, rights-of-way, or diverse-path inter-site fiber.
  • Working knowledge of AutoCAD, BIM, or cable-management tools used to produce pathway and cable documentation.
  • Experience commissioning new-build sites and turning over labeled, tested, as-built Layer 1 packages to operations.

Responsibilities

  • Plan and coordinate copper and fiber infrastructure for SCADA, protection, metering, auxiliary power, client, security, and other non-compute support systems on new power-plant and AI-campus projects.
  • Develop pathway designs, conduit and manhole layouts, routing and diversity schemes, cable schedules, media selections, connector and splice standards, and labeling conventions.
  • Specify media suitable for the environment, including outdoor, armored, or industrial-rated copper and single-mode or, where justified, multimode fiber, with appropriate indoor and OSP constructions.
  • Define test and acceptance criteria, including OTDR, optical loss testing, and copper certification, and review contractor test results against design loss budgets and redundancy requirements.
  • Produce construction packages and coordinate with civil, electrical, mechanical, controls, and construction teams through design, procurement, installation, and commissioning.
  • Sequence pathway work so conduit and tray are installed before cable.
  • Manage low-voltage and fiber contractors, including installation quality, fusion-splice oversight, as-builts, and documentation meeting plant and site standards.
  • Plan site-to-site and inter-building links, including diverse physical paths and handoffs at demarcs, without extending ownership into the data hall.
  • Maintain clear demarcation with data-hall cabling teams so supporting-system infrastructure and compute-fabric infrastructure remain separate.
  • Apply relevant codes and practices, including NEC, TIA-568, TIA-758 where applicable, BICSI methods, and utility or IEEE practices for power-system communications.
  • Support the availability and path diversity expected of SCADA and critical auxiliary systems.