Non-Destructive Evaluation and Testing Engineer

University of Oklahoma•Norman, OK
•Onsite

About The Position

The Sooner Advanced Manufacturing Laboratory (SAML) at the University of Oklahoma, operating under the Office of the Vice President for Research and Partnerships (OVPRP), is seeking a Non-Destructive Evaluation and Testing Engineer. The engineer serves as the lead technical expert for SAML's high-energy industrial microfocus X-ray Computed Tomography (CT) system, a ZEISS METROTOM 800 320kV. The role involves developing scan protocols, optimizing high-voltage penetration parameters, performing 3D volumetric reconstructions, evaluating internal defect structures such as porosity, voids, and inclusions, and conducting high-precision coordinate metrology. The work supports qualification and airworthiness certification frameworks for aerospace and defense applications and contributes to technical training programs for the Air Force Sustainment Center (AFSC) and Oklahoma City Air Logistics Complex (OC-ALC). This is an on-site position at SAML's manufacturing facility in Norman, Oklahoma. Travel may be required. The work schedule is Monday through Friday, 8:00 a.m. to 5:00 p.m., and may include some weekends.

Requirements

  • Bachelor's degree.
  • 3 years of related experience.
  • U.S. citizenship and the ability to obtain and maintain a U.S. Security Clearance.

Nice To Haves

  • Master's degree in Materials Science, Mechanical Engineering, Aerospace Engineering, Physics, Electrical Engineering, or a related discipline.
  • 1 to 5+ years of hands-on experience operating industrial X-ray CT systems or high-precision 3D coordinate measuring machines (CMMs).
  • Proficiency with ZEISS METROTOM OS, ZEISS INSPECT X-ray Pro, or equivalent volumetric analysis software such as Volume Graphics VGSTUDIO MAX.
  • Solid understanding of X-ray physics, beam attenuation, and artifact mitigation techniques for high-density metal specimens, including scatterControl, beam hardening, and ring artifact reduction.
  • Knowledge of ASME Y14.5 Geometric Dimensioning and Tolerancing (GD&T) principles and nominal-to-actual CAD-to-mesh verification.
  • Experience utilizing Python scripting APIs for automated batch processing and data extraction.
  • ASNT Level II or III certification in Radiographic Testing (RT) / Computed Tomography (CT), AUKOM Level 1, or formal radiation safety credentials.

Responsibilities

  • Serve as the lead technical expert for SAML's ZEISS METROTOM 800 320kV industrial microfocus X-ray CT system.
  • Develop scan protocols and optimize high-voltage penetration parameters.
  • Perform 3D volumetric reconstructions.
  • Evaluate internal defect structures, including porosity, voids, and inclusions.
  • Execute high-precision coordinate metrology.
  • Support qualification and airworthiness certification frameworks for aerospace and defense applications.
  • Contribute to technical training programs for the Air Force Sustainment Center (AFSC) and Oklahoma City Air Logistics Complex (OC-ALC).
© 2026 Teal Labs, Inc
Privacy PolicyTerms of Service