About The Position

Under the supervision of a registered nurse, the Monitor Technician monitors, recognizes, and interprets cardiac rhythms; identifies deviations from patients’ baselines and changes in SpO2; and notifies the registered nurse of changes in a patient’s status. The technician initiates the appropriate emergency response by the critical care team in the event of a lethal arrhythmia, including irregular heart rhythms and cardiac arrest. The role requires knowledge of cardiac anatomy and physiology, telemetry services, and ECG/EKG interpretation. The technician works with minimal supervision in a potentially stressful environment, responds appropriately to interruptions and changing workloads, and sits for extended periods while monitoring and interpreting cardiac rhythms.

Requirements

  • Monitor Technician certification is required.
  • Electrocardiogram (ECG/EKG) competency is required.
  • Successful completion of ECG/EKG interpretation coursework is required.
  • At least six months of experience after completing a Monitor Technician Extern program, or at least six months of experience in lieu of vocational technical education if not a graduate of the program.
  • Knowledge of heart anatomy and physiology as it relates to waves, complexes, time, voltage, the conduction system, and strip interpretation.
  • Knowledge of telemetry services.
  • Critical thinking, effective communication, and decisive judgment skills; ability to work with minimal supervision.
  • Ability to work in a stressful environment and take appropriate action.
  • Ability to sit for extended periods while monitoring and interpreting cardiac rhythms.
  • Ability to handle frequent interruptions and adapt to changes in workload and work schedules.
  • BLS certification from the American Heart Association or Red Cross, or the listed grace-period credential, is required.

Responsibilities

  • Attach electrodes to patients to record cardiac electrical impulses for continuous ECG monitoring and identify and correct artifacts.
  • Report abnormal telemetry findings or changes in a patient’s monitoring to nursing staff, the immediate supervisor, or the designated chain of command.
  • Continuously and simultaneously monitor complex cardiac monitoring systems, including ECG rhythm screens, computerized dysrhythmia detection systems, and rhythm printers.
  • Maintain accurate, neat patient logs documenting cardiac monitoring status, rhythms, rhythm changes, and changes in patient condition.
  • Update patient records with readings taken from heart monitors or EKGs.
  • Activate an emergency or rapid response for a lethal arrhythmia or cardiac arrest.
  • Identify arrhythmias, deviations from patient baselines, and signs of deterioration, and intervene to ensure patient safety.
  • Document electrocardiograph tracings for patients on telemetry monitors.
© 2026 Teal Labs, Inc
Privacy PolicyTerms of Service