GW Monitoring Technician

GlobalstarCovington, LA
Onsite

About The Position

The Facilities BMS Technician performs the hands-on technical work of instrumenting Gateway facility infrastructure for monitoring and building the visualizations and alarming that keep critical sites observable around the clock. This role configures equipment for monitoring at the device and protocol level, implements and maintains coverage in the monitoring platforms (Virtana (previously Zenoss) and Grafana), and develops and maintains the Virtana and Grafana graphs, dashboards, and visualizations used across the global Gateway fleet.

Requirements

  • Hands-on experience with network/infrastructure monitoring platforms (Virtana, Zenoss, or comparable such as SolarWinds, PRTG, or LibreNMS)
  • Proficiency building and maintaining Grafana dashboards, including data source configuration, and alerting
  • Working knowledge of SNMP and MIB/OID structures, Modbus (TCP/RTU), and BACnet/IP
  • Familiarity with BMS/DDC platforms (Niagara/JACE)
  • Understanding of critical facility equipment — UPS, ATS/STS, generators, CRAC/CRAH, PDUs, power metering, and environmental sensors
  • Networking fundamentals (TCP/IP, VLANs, and firewall rules for monitoring traffic)
  • Excellent organizational skills with attention to detail
  • Data-oriented, with the ability to validate and reconcile data against source equipment
  • Excellent verbal and written communication skills across departments and levels of management
  • Ability to meet multiple deadlines and prioritize tasks in a fast-paced environment
  • Ability to act with integrity, professionalism, and confidentiality
  • Cross-cultural communication
  • Associate or Bachelor's degree in electronics, electrical, instrumentation and controls, network/IT, or a related technical discipline.
  • Equivalent combination of relevant qualifications and experience may substitute for the degree.
  • 3+ years in monitoring, NOC, BMS/controls, instrumentation, or comparable roles within critical facilities, data centers, telecom/teleport, utilities, or industrial 24/7 operations
  • Demonstrated hands-on configuration of monitoring platforms and dashboards.
  • Experience integrating equipment via SNMP, Modbus, and/or BACnet.

Nice To Haves

  • Basic scripting and query skills (e.g., PromQL/Flux, SQL, Python, or shell) are an advantage
  • Certifications are an advantage: Grafana certification, networking certifications (CompTIA Network+, CCNA), and BMS/controls certifications (e.g., Tridium Niagara).

Responsibilities

  • Configure facility infrastructure — UPS, ATS/STS, generators, CRAC units, PDUs, power meters, environmental sensors, and other equipment — for remote monitoring via SNMP, Modbus, and BACnet/IP.
  • Build and maintain device monitoring in Virtana and Zenoss, including discovery, MIB/OID mapping, polling and template configuration, graphs, thresholds, and alarm/event setup.
  • Develop and maintain Grafana dashboards across the monitoring hierarchy.
  • Configure Grafana data sources, panels, variables, alerting rules, and access controls.
  • Translate commissioning and client datapoint/alarm requirements into implemented monitoring coverage and identify instrumentation gaps.
  • Identify and map SNMP OIDs and MIBs for equipment.
  • Configure BMS/BACnet and Modbus points where native vendor SNMP is unavailable, and coordinate with controls vendors on BACnet and Niagara/JACE integration.
  • Validate polled values against equipment displays and commissioning records, and document the resulting point and register mappings.
  • Maintain monitoring documentation per site: point lists, OID/register maps, dashboard inventories, naming conventions, and as-built monitoring records.
  • Follow and contribute to Gateway monitoring standards, and process all monitoring configuration changes through change control.
  • Keep per-site monitoring as-builts current as equipment and coverage change.
  • Support commissioning and site-readiness validation by configuring and verifying monitoring for new and upgraded equipment.
  • Participate in datapoint reviews and verify alarm and threshold configuration against the approved test plans prior to handover.
  • Triage and resolve monitoring gaps, false or nuisance alarms, and stale or missing points, and tune thresholds for actionable alarming.
  • Support the facilities team and OCC with monitoring data, reports, and dashboard requests.
  • Drive improvements to monitoring coverage, reliability, and visualization quality across the Gateways.
  • Work on concurrent monitoring deployments, sometimes across multiple geographical regions.
  • Conduct on-site instrumentation and verification visits as needed and produce coverage and gap reports with recommended remediations.

Benefits

  • Paid Time Off
  • Paid Holidays
  • 401(k) Plan with Company Match
  • Employee Stock Purchase Program
  • Voluntary and Company Paid Group Life Insurance
  • Short- and Long-Term Disability Insurance
  • Medical FSA
  • Dependent Care
  • Competitive Salaries
  • Health Insurance
  • Dental Insurance
  • Vision Insurance
  • Employee Assistance Program
  • Comprehensive and Interactive Wellness Program
© 2026 Teal Labs, Inc
Privacy PolicyTerms of Service