FOE Program Lead

Georgia Green Energy Services Llc•ATLANTA, GA
•Onsite

About The Position

The FOE Program Lead owns the Company’s Foreign Object Elimination (FOE) program for the project, building and managing it day to day and serving as the Company’s single point of contact with the Client and trades. The Program Lead reviews all reports, findings logs, and the final closeout package before they are sent to the Client. The role is based at a project site in the Atlanta, Georgia metro area and reports to Company leadership (Project Principal). It supervises the FOE/FOD Field Inspector. This is a full-time, project-based assignment lasting eight weeks at 40 hours per week. The Program Lead establishes the program, coordinates inspections with the Client, construction trades, and commissioning team, participates in critical and high-risk field inspections, verifies corrective actions, oversees records and reporting, and ensures compliance with applicable safety and site requirements. The assignment includes a seven-year record-retention requirement.

Requirements

  • At least 8 years of experience in mission-critical or data center construction QA/QC, commissioning, or electrical testing.
  • At least 3 years leading an FOE/FOD, QA/QC, or commissioning program on site.
  • Working knowledge of NFPA 70E, NEC, NETA acceptance testing, and commissioning levels L1–L5.
  • Ability to read single-line diagrams, equipment drawings, submittals, and P6 schedules.
  • Clear technical writing skills, including producing factual, photo-backed findings tied to an equipment tag.
  • Current OSHA 30 and NFPA 70E training.
  • Ability to pass a drug and alcohol test and a site background or badging check.
  • Ability to complete I-9 employment eligibility verification.
  • Ability to walk full shifts, climb ladders, work at heights and in tight equipment spaces, lift up to 50 pounds, and wear required PPE throughout the workday, including arc-rated PPE where required.

Nice To Haves

  • Hyperscale data center experience with a large general contractor.
  • NETA Level III or IV certification, a commissioning credential, or a PE license.
  • A degree in electrical or mechanical engineering or a related field.
  • Experience with construction document platforms such as PMWeb, Procore, or ACC/BIM 360.

Responsibilities

  • Review the contract scope, project specifications (Divisions 23, 26, and 01 91 13 Commissioning), and current construction and commissioning schedule.
  • Build an equipment register by equipment tag for all electrical and mechanical equipment in scope.
  • Establish FOE zones and inspection points aligned with equipment setting, close-up, and energization milestones.
  • Write inspection checklists for switchgear, transformers, UPS, busway, panelboards, generators, AHUs, and liquid-cooling equipment.
  • Define findings severity levels, photo standards, and templates for daily field reports, findings logs, and weekly summaries.
  • Submit the FOE program plan to the Client and confirm how findings will be communicated before work starts.
  • Meet daily with the Client’s superintendent and QA/QC lead to set inspection priorities based on the look-ahead schedule.
  • Coordinate with electrical and mechanical trades and the commissioning team so inspections occur before covers are installed, equipment is closed up, or equipment is energized.
  • Report findings to the Client promptly enough to allow action before close-up or energization.
  • Attend project coordination and commissioning meetings as requested by the Client.
  • Give FOE awareness briefings to trade crews when requested by the Client.
  • Perform FOE/FOD inspections alongside the Field Inspector, focusing on critical and high-risk equipment.
  • Re-inspect equipment to verify reported findings were corrected and record their closure.
  • Escalate repeat findings, trends, and conditions that could cause equipment damage at energization.
  • Review and approve every daily field report and findings log entry before submission to the Client.
  • Prepare and issue weekly summaries covering inspections completed, findings opened and closed, trends, and open risks.
  • Build and deliver a final closeout package organized by equipment tag at the end of the assignment.
  • Keep reports, photos, and supporting data organized to meet the seven-year record-retention requirement.
  • Ensure the team follows the Company’s safety program and the Client’s site safety rules, including NFPA 70E boundaries.
  • Report accidents to the Client within two hours and provide a written report within 24 hours.
  • Track hours for both positions, obtain the Client’s written approval before any overtime, and submit billing backup to the Company before the 20th of each month.
  • Ensure reports and project photos are shared only with the Client or people the Client authorizes in writing, and are not used on social media, in marketing, or in personal files.
  • Follow the Client’s harassment-free workplace, gift, and anti-corruption policies.
© 2026 Teal Labs, Inc
Privacy PolicyTerms of Service