Facilities Maintenance Technician

Indotronix International Corporation•Frederick, MD

About The Position

The Facilities Maintenance Technician provides mechanical, utility, and mission-critical infrastructure services at a complex biotech manufacturing, distribution, research and development, and data center site. The role installs, repairs, troubleshoots, and performs preventive maintenance on facility, utility, and mission-critical IT support systems. The Senior Facilities Maintenance Technician performs advanced maintenance, contributes to GMP documentation, responds to critical alarms, and supports the Lead Facilities Maintenance Technician through technical execution and mentorship of lower-level personnel. This is a second-shift role, Monday through Friday, from 2:00 PM to 10:30 PM, with an on-call rotation. The technician supports continuous site operations, monitors infrastructure systems and alarms, helps restore critical environments after maintenance interventions, and supports commissioning and qualification, audits, and regulatory inspections. The position requires compliance with site EH&S requirements and applicable FDA, cGMP, and ISO requirements.

Requirements

  • At least 6 years of related facilities or utilities maintenance experience, including at least 3 years at a GMP-regulated biotechnology, pharmaceutical, or life sciences manufacturing site.
  • Proven working knowledge of electrical, plumbing, HVAC, and refrigeration equipment and systems.
  • Working knowledge of IT data center and mission-critical systems, including CRAC and UPS systems.
  • Ability to comply with FDA, EH&S, cGMP, and ISO regulations.
  • Advanced troubleshooting skills.
  • Strong working knowledge of BMS and CMMS.
  • Experience contributing to GMP documentation, including preventive maintenance procedures, SOPs, and GDP-compliant work order records.
  • Experience supporting emergency response, critical system recovery, and after-hours or on-call maintenance response.
  • High school diploma or equivalent.
  • Certification in multiple relevant mechanical and/or electrical trades.
  • Current EPA Section 608 Universal CFC certification.
  • Current OSHA 10-hour General Industry certification.
  • Valid driver's license.

Nice To Haves

  • Maryland Stationary Engineer license (any grade).
  • OSHA 30-hour General Industry certification.
  • Hands-on experience with Blue Mountain RAM or an equivalent validated GMP CMMS.
  • Hands-on experience with Siemens Desigo Insight, Siemens Desigo CC, Johnson Controls Metasys, Honeywell, or equivalent BMS platforms.
  • Boiler operator license (high or low pressure).
  • Ability to develop reliability reports that help identify areas of concern and potential future problems.
  • Communication, problem-solving, demeanor, pace, influencing, leadership, and negotiating skills.
  • Ability to work independently, in a group setting, with little direction, or under direct supervision.

Responsibilities

  • Develop and maintain a complete working knowledge of facility infrastructure systems and operations.
  • Respond to infrastructure, utility, and mission-critical IT equipment alarms, and perform repair and mitigation activities.
  • Restore critical environments to their original maintenance condition following repairs or interventions.
  • Support customer facility infrastructure needs to ensure continuous operations.
  • Troubleshoot HVAC, boilers, pure steam generators, autoclaves, glassware washers, laboratory washers, RODI, refrigeration, electrical, plumbing, and pneumatic systems.
  • Operate and support data center infrastructure, including CRAC units, UPS systems, and battery strings; escalate complex events to the Lead Facilities Maintenance Technician.
  • Perform preventive maintenance on equipment and building systems in accordance with department procedures.
  • Participate in emergency on-call rotation.
  • Guide, train, and coach lower-level personnel on the job.
  • Author and revise preventive maintenance procedures, SOPs, job plans, and work instructions.
  • Contribute to GMP quality records, including Change Controls, Deviations or Problem Reports, CAPAs, and MOPs; author records independently when assigned.
  • Complete work order documentation in accordance with GDP and ALCOA+ data integrity principles.
  • Maintain accurate CMMS records of building operations, repairs, parts, equipment condition, and preventive maintenance activities.
  • Use the BMS to monitor alarms, review trends, and support troubleshooting.
  • Monitor critical plant systems through rounds, meter readings, BMS trend reviews, and field inspections.
  • Record daily meter readings and identify adverse trends for escalation.
  • Coordinate planned work in data center and server room spaces with site IT, following mission-critical change control procedures.
  • Support commissioning and qualification (IQ, OQ, and PQ) of new and modified utility and facility systems as assigned.
  • Support audits and regulatory inspections by providing requested records and answering subject matter questions within the role's scope.
  • Comply with site EH&S requirements, including Lockout/Tagout, confined space, hot work, electrical safety, fall protection, refrigerant handling, and chemical safety.
  • Identify recurring failures and reliability opportunities and recommend improvements to the Lead Facilities Maintenance Technician and Facility Manager.
  • Help ensure continuous operation of site HVAC, utility, and mission-critical IT support systems.
  • Perform other related duties as required or assigned.
© 2026 Teal Labs, Inc