Electroencephalograph (EEG) Tech

Hennepin Healthcare•Minneapolis, MN

About The Position

The EEG Tech works under general supervision in the EEG Diagnostic Lab, performing computerized recordings of routine, sleep-deprived, long-term, portable, and ICU EEGs. The role provides a safe environment while maintaining rapport with patients and their families and following EEG Lab policies and procedures. The technologist evaluates patient condition and ability to participate, prepares patient data, applies and checks electrodes, verifies and calibrates digital EEG equipment, and obtains standard recordings with appropriate activation procedures. The technologist adapts recording methods to the referral reason, patient history, observed waveforms, and clinical setting; recognizes and documents artifacts and clinical observations; and removes electrodes and reviews recordings for appropriate documentation when testing is complete. The position also requires working knowledge of neuroanatomy, neurophysiology, neurological and psychiatric disorders, seizure patterns, EEG waveforms, electronics, and recording principles. The technologist maintains and improves professional knowledge through regular review of EEG tracings, reading, study, and continuing education.

Requirements

  • Six months of experience performing electroencephalograph tests, completion of an approved training program in EEG testing, or an approved equivalent combination of education and experience.
  • Strong communication skills.
  • Ability to collaborate with and take direction from physicians and other clinical team members.
  • National Board Registration required within 24 months of employment.

Responsibilities

  • Provide a safe recording environment by verifying patient identity, cleaning electrodes, following infection-control and biohazard procedures, attending to patient needs, responding to life-threatening situations, maintaining equipment, and observing electrical-safety precautions.
  • Build rapport with patients and families; explain test and activation procedures and electrode application; communicate in a manner appropriate to the patient’s age and mental capacity; and maintain respect and confidentiality.
  • Evaluate the patient’s mental age, mental state, comprehension, physical condition, ability to cooperate, and special needs; determine appropriate electrode application, whether hyperventilation is contraindicated, the need for physiological monitors, and whether immobilization, emergency intervention, or interpreter services may be needed.
  • Document behavior suggestive of seizure or pseudo seizure and other relevant patient observations.
  • Prepare the patient data sheet using EPIC information, pertinent patient and family medical history, medications and sedation, seizure or symptom details, mental and behavioral state, and diagrams of skull defects or electrode-placement modifications.
  • Measure and mark the head using the international 10/20 system; adapt placement for anatomical defects; prepare the scalp; apply electrodes using paste or collodion and electrolyte; and verify electrode impedances meet stated criteria.
  • Document digital EEG instrument working condition by calibrating amplifiers and verifying filter and sensitivity settings, applying a biological signal to all channels, and correcting or reporting deviations.
  • Obtain a standard EEG recording of at least 20 minutes of technically acceptable data, including appropriate eye opening and closing, hyperventilation when clinically appropriate, photic stimulation, mental stimulation or assessment, impedance checks, and drowsiness or sleep when possible; note behavior and clinical seizure manifestations.
  • Customize procedures according to the referral reason, history, and waveforms; select appropriate montages and instrument settings; use techniques to enhance clinical symptoms; encourage sleep; add electrodes to localize abnormalities; and monitor respiration or ECG when appropriate.
  • Follow technical criteria for recording electrocerebral inactivity, neonatal and pediatric EEG, and EEGs in intensive care or cardiac care units.
  • Differentiate artifacts from cerebral waveforms, document patient movements, apply or record eye-potential and ECG leads, replace electrodes with questionable activity or contact, and troubleshoot electrical interference.
  • After recording, remove electrode paste or glue from the patient’s scalp and hair, describe clinically significant behavior, document sedation and its effects, and review the EEG for documentation of amplifier settings and montage changes.
  • Maintain and improve knowledge and skills by reviewing EEG tracings with an EEGer, reading journal articles and textbooks, and attending continuing education courses in electroneurodiagnostics.
  • Apply electronics and mathematics principles to recording, including understanding differential amplifiers, waveform polarity, impedance, and analog-to-digital conversion.
  • Recognize normal, normal-variant, and abnormal awake and asleep patterns across age ranges, EEG patterns associated with levels of consciousness, and clinical seizure patterns.
© 2026 Teal Labs, Inc
Privacy PolicyTerms of Service