Electrical/Instrumentation Inspector

E2 Consulting Engineers, LP•Catarina, TX
•Onsite

About The Position

The Electrical/Instrumentation Inspector oversees Quality Assurance for electrical and instrumentation installation and testing on natural gas transmission facility construction or modification projects. The role ensures construction, pre-commissioning, commissioning, and testing activities comply with project specifications, drawings, applicable codes and regulations, industry standards, and safety and environmental requirements. The inspector coordinates with utility representatives and contractor personnel, witnesses and documents inspections and tests, maintains construction and as-built records, and escalates issues to the direct report. Work takes place primarily at construction sites and client rights-of-way, with occasional work at a client testing facility or corporate office. The role may require extensive driving to job sites and client or E2 offices. It involves frequent climbing and movement around construction areas, lifting objects over 50 pounds, visual inspection and use of measuring devices, and working indoors and outdoors in extreme heat or cold across the continental United States. Candidates must be local to the project area.

Requirements

  • At least five years of field-based experience providing electrical inspections on plant or station construction and modification projects for natural gas transmission facilities.
  • Experience across all phases of electrical and instrumentation construction, including handling, inspection, installation, testing, commissioning, and start-up.
  • Broad knowledge of electrical, instrumentation, and control-system construction, commissioning, and inspection best practices.
  • Knowledge of electrical construction inspection, quality assurance, quality control, and safety-related construction requirements.
  • Knowledge of construction grounding requirements, stray-current mitigation, and related electrical safety requirements.
  • Ability to use test meters to check electrical circuit continuity and oversee contractor work involving such testing.
  • Knowledge of relevant codes and standards, including NFPA 70 (National Electrical Code) and 49 CFR Part 192.
  • Current, valid driver's license, which must be maintained.
  • Submit inspector qualifications to the Company for review and approval before services commence.

Nice To Haves

  • Technical degree.
  • OSHA certification.
  • Word and Excel computer skills.

Responsibilities

  • Review construction specifications, drawings, and project requirements, particularly those for electrical and instrumentation installation and testing.
  • Communicate daily with the Company Utility Power Coordinator or Company Utility Power ROW agent about construction activities needed before local utility companies provide power to the site.
  • Provide Quality Assurance oversight for construction, pre-commissioning, and commissioning of electrical, instrumentation, telecommunication, test lead, AC mitigation, and CP systems.
  • Follow up with contractor testing teams and foremen to confirm timely receipt of required test records and reports.
  • Verify, inspect, and witness electrical components in substations, including transformers, switchgear, control panels, distribution boards, batteries and chargers, busbars, UPS systems, motor control centers, and generator sets.
  • Inspect and witness testing of HV and LV cables and pre-commissioning of transformers, generators, motors, and motor control centers.
  • Witness no-load motor tests and testing of power and control systems, switchgear, control cables, local control stations, lighting panels, and plant earthing systems.
  • Inspect electrical and instrumentation installations, cable trays, above- and below-grade conduit, and fiber-optic cable installation and testing.
  • Maintain records, including as-built data; audit contractor as-built drawings; and ensure drawings are accessible at the construction site and turned over to ET within seven days after the in-service date.
  • Confirm completion of the Arc Flash study and posting of equipment stickers.
  • Inspect and oversee cable glanding, termination, and dressing; witness cable insulation resistance and continuity tests at specified stages and final torquing of cable terminations.
  • Witness instrument calibration, installation, impulse and air tubing installation, and leak testing.
  • Witness field instrument and junction-box installation, field calibration and testing, cable meggering and continuity checks, instrument component inspections, loop checks, and functional testing of instruments, loops, analog and digital signals, and the ESD system.
  • Inspect ground rods and grounding cables against specifications, instrument stanchions, and fiber-optic cable installation and terminations; confirm seals are poured after checkouts.
  • Ensure final grade, finish rock, and perimeter fencing are installed when the I/E contractor is the only contractor remaining.
  • Verify work complies with applicable local, state, and federal rules, regulations, codes, industry standards, and Company specifications.
  • Oversee project safety and environmental requirements and attend contractor safety meetings.
  • Record contractor progress and activities daily, including completed and skipped work locations and reasons, witnessed test results, and weather or logistical conditions affecting progress.
  • Complete reports legibly with dates and signatures and include photographs; immediately escalate issues to the direct report.

Benefits

  • Health insurance
  • Dental insurance
  • Vision insurance
  • Life insurance
  • 401(k) with employer match
© 2026 Teal Labs, Inc