Datacenter MEP Field Engineer

Hydra Host•Miami, FL
•Onsite

About The Position

Hands-on Field Engineer that owns liquid cooling and HVAC infrastructure in GPU compute environments. This role involves managing Cooling Distribution Units (CDUs), direct-to-chip loops, facility water plants, precision air handling, power distribution, power chain assessment, and power analysis management at rack densities where miscalculations can take hardware offline.

Requirements

  • Any Journeyman MEP Trade License or higher.
  • Several years of datacenter mechanical/electrical installation, and commissioning.
  • Hands-on liquid cooling experience at 75+ kW/rack—CDUs, direct-to-chip, rear-door HX, or immersion.
  • Familiarity with N+1/2N redundancy architectures for cooling plants and concurrently maintainable designs.
  • Willing to travel for site surveys, construction oversight, and commissioning.

Nice To Haves

  • Portfolio showcasing designed or delivered projects, including CDU install docs, HVAC load calcs, One-Line Power Train diagrams, commissioning reports with thermal data, piping schematics, conduit installations, construction photos, capacity models.
  • Personal site, portfolio, or reference list of completed facilities.

Responsibilities

  • Evaluate and commission liquid cooling for GPU compute, including CDUs, direct-to-chip cold plates, reardoor HX, immersion tanks, and chilled water plants.
  • Size heat rejection from real TDP data.
  • Manage PDU/UPS/XFR/ATS/STS from Medium Voltage to Low Voltage transformation, inversion, rectification, and power distribution one-lines.
  • Oversee CRAH/CRAC/CDUs, hot/cold aisle containment, economizers, humidification, and supplemental cooling for mixed air/liquid deployments.
  • Specify piping for liquid cooling loops, including routing, glycol concentration, pump curves, flow balancing, filtration, expansion tanks, and leak detection.
  • Perform thermal validation under load, including delta-T, flow rate verification, coolant pressure testing, and refrigerant charge validation.
  • Coordinate with mechanical subcontractors, vendors, and controls integrators to prevent trade conflicts.
  • Integrate DCIM/BAS for cooling monitoring and electrical capacity management.
  • Perform datacenter mechanical/electrical installation and commissioning.
  • Manage liquid cooling systems at 75+ kW/rack, including CDUs, direct-to-chip, rear-door HX, or immersion.
  • Ensure N+1/2N redundancy architectures for cooling plants and concurrently maintainable designs.
  • Travel for site surveys, construction oversight, and commissioning.
© 2026 Teal Labs, Inc
Privacy PolicyTerms of Service