L2 - Data Center Field Installations Technician

TEKsystemsColorado City, TX
$30 - $48Onsite

About The Position

The Data Center Field Installations Technician (L2) is a developing technical role responsible for executing and overseeing in-rack installation activities of moderate complexity within a data center environment. This includes rack builds, equipment installation, structured cabling, power distribution, advanced cooling integration (DX and direct-to-chip liquid cooling), and initial system bring-up activities. This role works with greater autonomy and is responsible for interpreting installation designs, validating work quality, and supporting troubleshooting during deployment activities. Through proactive coordination and problem-solving, this role ensures installations are completed efficiently, accurately, and in alignment with technical standards and project timelines. The primary objective of this role is to deliver high-quality installation and validation outcomes while minimizing delays, rework, and SLA risks. The Data Center Field Installations Technician (L2) is responsible for managing standard to medium-complexity installation tasks, guiding L1 technicians, and resolving issues encountered during implementation.

Requirements

  • Proven experience in data center installations or similar hands-on technical role
  • Strong understanding of rack infrastructure, server, storage, and network hardware
  • Proficiency in structured cabling (fiber and copper) and cable management best practices
  • Experience with power distribution within racks (PDUs, dual feeds, redundancy concepts)
  • Working knowledge of cooling methodologies: DX airflow management within racks, Direct-to-chip (D2C) liquid cooling systems (installation, connection handling, and basic validation)
  • Experience with system deployment activities: OS installation and imaging tools (e.g., PXE, ISO-based installs, or automated deployment tools), Basic BIOS/firmware configuration and hardware validation
  • Familiarity with post-install validation and quality assurance processes
  • Ability to read and interpret technical drawings, schematics, and MOPs
  • Strong troubleshooting and problem-solving skills during installations
  • Ability to work independently and guide junior technicians
  • Good understanding of health and safety regulations in data center environments
  • Physically capable of performing installation tasks in demanding environments

Responsibilities

  • Lead rack build and in-rack deployment activities based on design documentation
  • Interpret rack layouts, elevation diagrams, and cabling schematics
  • Perform and validate rack & stack activities for servers, storage, and network equipment
  • Execute and verify structured cabling (fiber and copper), including basic testing/validation
  • Install and validate power connections (single/dual feed, PDUs, load considerations)
  • Implement and optimize cooling solutions: Configure airflow best practices for DX-cooled environments, Install and validate direct-to-chip (D2C) liquid cooling systems, including cold plates, hoses, manifolds, and quick disconnects, Perform visual inspections for leaks and ensure proper routing, strain relief, and secure connections
  • Perform initial system bring-up activities: Execute OS installation and basic configuration (in line with build standards and imaging processes), Validate hardware functionality (POST checks, BIOS/firmware baseline verification), Perform basic network connectivity checks where required
  • Conduct post-installation quality assurance: Verify installations against design specifications and checklists, Perform cable, power, and labeling audits, Validate airflow and cooling setup (DX and D2C), Identify and remediate defects or escalate issues
  • Identify and resolve installation issues, escalating when required
  • Support and guide L1 technicians on best practices and procedures
  • Coordinate with project teams, engineering, and operations for smooth delivery
  • Update documentation and report installation progress and deviations
  • Ensure compliance with all data center safety standards, permits, and procedures
  • Actively promote safe working practices and intervene in unsafe situations
  • Apply electrical safety awareness when working with powered equipment and PDUs
  • Follow and enforce safe handling procedures for direct-to-chip liquid cooling systems (including leak prevention and response)
  • Ensure proper use of PPE by self and supporting team members
  • Conduct risk awareness during installations (e.g., heavy lifts, cable congestion, liquid connections)
  • Maintain high standards of housekeeping and workspace safety
  • Report and escalate hazards, incidents, and non-compliance issues

Benefits

  • Medical, dental & vision
  • Critical Illness, Accident, and Hospital
  • 401(k) Retirement Plan – Pre-tax and Roth post-tax contributions available
  • Life Insurance (Voluntary Life & AD&D for the employee and dependents)
  • Short and long-term disability
  • Health Spending Account (HSA)
  • Transportation benefits
  • Employee Assistance Program
  • Time Off/Leave (PTO, Vacation or Sick Leave)
© 2026 Teal Labs, Inc
Privacy PolicyTerms of Service