About The Position

The Data Center Electrician will perform and support data center electrical deployment activities from overhead busway through cabinet-level power. This role will install and validate power equipment, support safe cabinet energization, replace in-rack power distribution units (PDUs), and help to maintain redundant, balanced, and reliable critical power paths. Work will be coordinated closely with Salute site leadership.

Requirements

  • Hands-on experience with commercial, industrial, or mission-critical electrical distribution systems.
  • Working knowledge of overhead busway, tap boxes, breakers, cabinet power whips, grounding and bonding, rack PDUs, and three-phase power concepts.
  • Demonstrated ability to read electrical one-line diagrams, power plans, equipment labels, and installation documentation.
  • Current NFPA 70E training and qualification to perform assigned electrical work, or the ability to obtain required qualification before assignment.
  • Applicable electrical license, credential, or employer authorization required by the work location and assigned task.
  • Ability to use electrical test equipment and torque tools safely and accurately within the individual's training and authorization.
  • Strong documentation, communication, and coordination skills in an active data center environment.
  • Work in an active data center environment and comply with all site access, personal protective equipment, and safety requirements.
  • Safely lift, position, and handle tools, cabling, tap boxes, and rack-level electrical components within established team-lift and equipment-handling limits.
  • Work at elevation using approved access equipment and perform tasks around overhead busway and cabinet infrastructure, as authorized.
  • Support scheduled deployment windows, maintenance periods, or off-hours energization activities when required.

Nice To Haves

  • Experience supporting live data center deployments, cabinet energization, or critical power operations.
  • Experience with redundant A/B power architectures, UPS capacity management, load balancing, and infrared thermography.
  • OSHA 10/30, lockout/tagout, first aid/CPR, or related site-safety training.

Responsibilities

  • Inspect overhead busway conditions before installation and identify visible defects or unsafe conditions.
  • Install customer-provided tap boxes in accordance with approved electrical layouts and designated cabinet power assignments.
  • Verify placement, orientation, electrical security, breaker sizing, labeling, and applicable torque requirements.
  • Support busway maintenance activities, including infrared (IR) scanning, as assigned.
  • Complete required installation documentation and activity reporting.
  • Route and secure cabinet power whips from tap boxes to customer cabinets.
  • Connect cabinet input power and verify cable integrity, connection points, and phase configuration where applicable.
  • Confirm labeling and complete a cable-management review.
  • Verify cabinets are securely mounted and stabilized and proper grounding/bonding installed, free of visible damage, and configured in accordance with approved documentation.
  • Confirm the cabinet and surrounding work area are safe and ready for energization.
  • Coordinate energization with operations teams; activate breakers and validate voltage in accordance with approved procedures and authorization.
  • Confirm successful cabinet power-up and document completed energization activities.
  • Remove failed or designated in-rack PDUs and install approved replacements.
  • Reconnect server power cords, restore orderly cable management, and verify cord connections.
  • Perform functional verification and confirm restored cabinet operation.
  • Validate cabinet power assignments to maintain end-to-end A/B redundancy and avoid introducing single points of failure.
  • Confirm loads are balanced across UPS systems and remain within defined capacity and operating limits.
  • Monitor circuit loading and escalate conditions that could create overload or redundancy risk.
  • Coordinate distribution changes with site operations and customer stakeholders.
  • Maintain alignment with approved electrical one-line diagrams and power plans throughout deployment.
  • Perform work in accordance with site electrical safety policies, lockout/tagout requirements, approved procedures, and applicable codes and standards, including NFPA 70E.
  • Coordinate with site operations and customer representatives before energization or other electrical switching activities. Exercise best practices to minimize disruption and maintain equipment integrity during all replacement activities.
  • Prepare required energized electrical work permit documentation; CoreWeave retains responsibility for review and approval of work performed in accordance with NFPA 70E.
  • Stop work and promptly escalate unsafe conditions, damaged equipment, design conflicts, capacity concerns, or deviations from approved plans.

Benefits

  • 8 company-paid holidays
  • 2 floating holidays
  • PTO
  • Medical, Dental, and Vision insurance
  • Employee Assistance Program
  • Employer-supported 401(K) with immediate 100% vesting
  • 3% employer match on 401(K)
  • 50% match on the next 2% of 401(K)
  • HSA
  • Mental health resources
  • Gym discounts
  • Discounted group programs
  • Legal services
  • Home & auto insurance
  • Pet insurance
  • ID theft protection
  • Parental leave
© 2026 Teal Labs, Inc
Privacy PolicyTerms of Service