Commissioning Engineer - Data Center

BlackRock Resources•Jeffersonville, OH
•Onsite

About The Position

This onsite contract role supports data center construction commissioning in Jeffersonville, Ohio. The engineer leads mechanical, electrical, and plumbing (MEP) commissioning activities for mission-critical infrastructure, including L2–L5 testing, integrated systems testing (IST), and handover to client (H2C). The position coordinates client teams, commissioning authorities, contractors, subcontractors, and owner-furnished, contractor-installed (OFCI) vendors to support installation, energization, testing, issue resolution, and handover. The schedule is five 10-hour days plus eight hours on Saturdays. Pay starts around $50 per hour, with higher rates available based on matching qualifications. Applicants must be able to work in the United States without current or future sponsorship.

Requirements

  • Bachelor’s degree in Mechanical Engineering, Electrical Engineering, or a related field, or equivalent experience.
  • At least 4 years of experience in data center commissioning, MEP construction, or mission-critical environments.
  • Familiarity with data center infrastructure, including UPS systems, generators, switchgear, HVAC, and cooling systems.
  • Experience with commissioning processes (L2–L5), IST, and system startup and testing.
  • Familiarity with OFCI equipment, vendor coordination, and field execution in complex construction environments.
  • Experience with project scheduling tools such as Primavera P6 and critical-path tracking.
  • Ability to work in the United States without sponsorship now or in the future.

Responsibilities

  • Manage L2–L3 commissioning activities, schedules, and testing to achieve H2C.
  • Support L4 and L5 commissioning by coordinating with the ACx and CxA to ensure contractors and OFCI vendors are available for daily activities.
  • Drive resolution of issues identified during testing, with support from contractors and vendors.
  • Manage schedule changes and align resources as necessary.
  • Serve as the Client’s technical subject matter expert for OFCI equipment and its integration into unloaded and loaded commissioning processes.
  • Create the H2C schedule with the Campus Lead, align it with the P6 project schedule, manage it after creation, and conduct progress reviews with the project scheduler as needed.
  • Coordinate with Client Site Superintendents and subcontractors on pre-energization installation concerns and resolution meetings.
  • Assist OFCI in establishing the initial documentation framework for L2–L3 inspections with the Client CM and ACx.
  • Align the energization plan with the Client’s MEP and Electrical Energy Marshals.
  • Track post-energization activities against the energization plan, provide guidance on deviations, and escalate vendor support requests as needed.
  • Ensure vendors and subcontractors complete L2–L3 site testing according to project schedules.
  • Plan and coordinate activities involving multiple vendors, subcontractors, ACx, or DCEO, including DLB, busduct tie-ins, and MCMs; resolve obstructions to planned testing.
  • Support L4–L5 testing by driving closure of observations and inspections, facilitating support from site superintendents and subcontractors, communicating and ensuring execution of the load-bank plan, and addressing commissioning concerns with vendors and subcontractors.
  • Coordinate IST-day activities, including opening the outside-air reference valve with the mechanical contractor, confirming removal of the air sail between construction and live sides, and staging load banks with an operator through testing, including necessary lunch and after-hours overlaps.
  • Coordinate post-IST load-bank removal, DAHU filter changes, and installation of HAC with the relevant contractors and site superintendent, except where racks are already placed.
  • Confirm IST has passed by emailing superintendents, project managers, electrical and mechanical contractors, and commissioning support.
  • Assist DCEO with Live Load Transfer testing as necessary and help site superintendents identify housekeeping items before the PFHO walk with the Client team.
  • Assist OFCI with technical specifications and investigations of potential equipment damage or deviations from approved submittals; support OFCI critical-path items and resource scheduling.
  • Track project delays and record lessons learned.
  • Participate in daily construction coordination meetings and weekly Client, OAC, and MCM meetings; manage weekly L2/L3 meetings two to three times per week.
  • Track the H2C schedule and coordinate TAB, tie-ins, DLB, MCMs, Client Observation resolution, and inspection completion.
  • Participate in daily L4/L5 commissioning meetings, drive observation resolution, and communicate issue resolution to the CxA and ACx.
  • Support loaded-system testing, integrated-system testing, load banks, and DAHU, REFA, and damper activities with the responsible electrical and mechanical contractors.

Benefits

  • Medical, dental, and vision benefits.
  • Paid holidays.
  • Accrued PTO.
  • 401(k) with company match.
© 2026 Teal Labs, Inc
Privacy PolicyTerms of Service