Requirements Engineering Intern – Data Center Rack

Bosch GroupSunnyvale, CA
2d$38 - $55

About The Position

Bosch Research is looking for a Requirements Engineering Intern for Data Center Racks. The duration of the internship is 3 months with a target start date of May 18, 2026. What you will do: Requirements collection and consolidation: Understand and reconcile published requirements from various sources with stakeholder interviews across electrical, thermal, mechanical, controls, safety, and sustainability domains; capture business, regulatory, and operator needs for 250–1,000 kW rack configurations. System requirements and architecture: Draft clear, testable system and subsystem requirements for power conversion (800 VDC→48 V→1 V), point‑of‑load rails, direct liquid cooling/CDU, energy buffering, and unified rack controls/telemetry. Standards and compliance mapping: Build compliance and gap analyses against relevant standards and guidance (e.g., OCP, ASHRAE liquid cooling classes, UL/IEC IT and power equipment, EMC/harmonics, NFPA electrical safety) and regional codes. Risk and reliability: Contribute to preliminary hazard analysis and FMEA for thermal, electrical, and fluid systems; align requirements with target KPIs for efficiency, leak rates, arc‑flash mitigation, fault isolation, and serviceability. Expected deliverables (3 months): Baseline system requirement specification for an integrated 1 MW rack architecture with clear acceptance criteria Standards compliance matrix and prioritized gap/risks list

Requirements

  • Currently pursuing a MS or PhD in electrical engineering, mechanical engineering, systems engineering, industrial engineering, or a related field
  • Minimum GPA of 3.0
  • Coursework or experience in two or more of: power electronics or DC power distribution; thermal/fluid systems and liquid cooling; embedded/controls/telemetry; reliability/safety engineering
  • Hands‑on experience with requirements engineering and systems thinking; ability to write clear, testable requirements and acceptance criteria
  • Strong technical communication skills, structured problem solving, and ability to work across disciplines under fast timelines

Nice To Haves

  • Exposure to data center infrastructures, liquid cooling, or high‑power conversion
  • Knowledge of relevant standards and practices and sustainability metrics
  • Experience with risk and reliability methods
  • Familiarity with telemetry and controls interfaces and data analysis scripting
  • Practical lab or hardware integration experience; comfort reviewing schematics, P&IDs, and layout drawings

Responsibilities

  • Requirements collection and consolidation: Understand and reconcile published requirements from various sources with stakeholder interviews across electrical, thermal, mechanical, controls, safety, and sustainability domains; capture business, regulatory, and operator needs for 250–1,000 kW rack configurations.
  • System requirements and architecture: Draft clear, testable system and subsystem requirements for power conversion (800 VDC→48 V→1 V), point‑of‑load rails, direct liquid cooling/CDU, energy buffering, and unified rack controls/telemetry.
  • Standards and compliance mapping: Build compliance and gap analyses against relevant standards and guidance (e.g., OCP, ASHRAE liquid cooling classes, UL/IEC IT and power equipment, EMC/harmonics, NFPA electrical safety) and regional codes.
  • Risk and reliability: Contribute to preliminary hazard analysis and FMEA for thermal, electrical, and fluid systems; align requirements with target KPIs for efficiency, leak rates, arc‑flash mitigation, fault isolation, and serviceability.
  • Baseline system requirement specification for an integrated 1 MW rack architecture with clear acceptance criteria
  • Standards compliance matrix and prioritized gap/risks list
© 2024 Teal Labs, Inc
Privacy PolicyTerms of Service